Replacing the safety glass
The safety glass can be removed by pressing the tension
spring.
Care
• The autocast universal
®
230 requires only a minimum
of care.
• Use a damp cloth to clean the surface.
Weekly maintenance
Cleaning the sinter filter:
Remove radiator from the melting chamber.
Unscrew filter – if necessary with a fork spanner SW 17 mm
from the melting chamber.
Clean the filter in ultrasonic bath.
After drying reassemble the filter in the reverse sequence.
Clean the reflector metal sheets in the casting chamber.
Remove the safety glass on the inside of the door and
clean it if necessary using a paper towel soaked in solvent.
If the glass is damaged or soiled by splashes of metal,
replace it.